CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride

Product Details
Customization: Available
Application Fields: Chemical
Certification: CE
Manufacturer/Factory, Group Corporation
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
90000 square meters
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001, HACCP, ISO 13485
  • CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
  • CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
  • CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
  • CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
  • CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
  • CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Technical Principle
  • Detailed Photos
  • Product Application
  • Certifications
Overview

Basic Info.

Model NO.
CDG-2000-ClO2
Noise Level
Low
Parts
Gas Tank
Purpose
Gas Manufacturing
Structure
Vertical
Types
Air separation equipment
Working principle
Electrolysis
Model
Cdg-2000-Clo2
Maximum Yield of Available Chlorine
2000g / H
Salt Consumption
1.6g / G Cl2
Power
<16kw
Voltage
380 AC V
Water Intake
DN40
Disinfectant Outlet
DN50
Sewage Outlet
DN25
Transport Package
Wooden Case
Trademark
WOBO
Origin
China
HS Code
8405100000
Production Capacity
50~10000 G / H

Product Description

High-Efficiency Chlorine Dioxide Generator, The First Choice for Pure Disinfection
CE Certificate Low Cost 50~10000G/H Chlorine Dioxide Generator for Phosphorus Pentafluoride

Product Description

 
CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
The chlorine dioxide generator is manufactured using advanced reaction technology and high-quality materials. The main body is usually made of corrosion-resistant stainless steel materials to ensure the durability and stability of the equipment. The internal reaction system is carefully designed to efficiently generate chlorine dioxide gas. There are various sizes available for selection according to different usage scenarios. When in use, connect the generator to the water source or air treatment system, and precisely control the output of chlorine dioxide by adjusting parameters to achieve the purpose of disinfection.

Product Parameters

 
 
Model Maximum yield of available chlorine Salt consumption Power Voltage Outer pipe diameter    
( g / h) ( g / g Cl2) (Kw) (AC V) water intake Disinfectant outlet Sewage outlet
CDG-2000-ClO2 2000 1.6 <16 380 DN40 DN50 DN25
CDG-3000-ClO2 3000 1.6 <24 380 DN40 DN50 DN32
CDG-4000-ClO2 4000 1.6 <32 380 DN40 DN50 DN32
CDG-4500-ClO2 4500 1.6 <36 380 DN40 DN50 DN32
CDG-5000-ClO2 5000 1.6 <40 380 DN40 DN50 DN32
CDG-10000-ClO2 10000 1.6 <80 380 DN40 DN50 DN32

Technical Principle


CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride

Working Principle of Chlorine Dioxide Generator:

The sodium chlorate aqueous solution and the hydrochloric acid solution are fed into the reactor by the metering pump, and the reaction is fully carried out under a certain temperature and negative pressure, and the output is mainly chlorine dioxide, which is absorbed by the water ejector and mixed with water to form a disinfectant. After that, pass it into the disinfected water.  

Detailed Photos

 
CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
  • Optimal raw material concentrations: HCl at 31% and NaClO3 at 27%, mixed in a 1:1 volume ratio.

  • Only domestic system with a five-stage reactor, achieving a total raw material conversion rate of ≥90%, with a chlorine dioxide to chlorine mass ratio greater than 1.

  • The reactor is made of titanium alloy, resistant to high temperatures, corrosion, and pressure.

  • Infrared heating technology ensures rapid heating with low power consumption, significantly reducing energy usage compared to similar products.

CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
  • Direct temperature measurement inside the reactor, with the protective sheath for the sensor made of titanium alloy.

  • The system uses dual temperature control, preheating the first four stages to 30-40°C and heating the fifth stage to 71°C.

  • Triple protection in the temperature control system.

  • A well-designed installation ensures no chlorine dioxide or corrosive gases indoors, along with zero noise and leakage pollution.

CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride
 

 

Product Application

  • Disinfection of life, drinking and tap water on various occasions;
  • Sterilization of restaurants, hotels, homes, tableware sanitary facilities, air environment disinfection, etc.
  • Final sterilization and disinfection of equipment, pipes, and containers in food and beverage factories and fermentation industries.
  • Sterilization of pipelines, facilities, and environment in dairy factories and slaughterhouses;
  • Sterilization and disinfection of hospital sewage;
  • Sterilization of swimming pool, industrial circulating water, and bathwater;
  • Anti-mold treatment for disinfection, sterilization, and deodorization of the hospital, sanitation, and clinical equipment;
  • Preservation and final washing and disinfection of foods such as homes, hotels, restaurants, fruits, vegetables, fish, and meat;
  • Equipped with various oral disinfectants, deodorants, and wound cleaning solutions.
  • Sterilization and deodorization in wastewater reuse;
  • Bleaching agent for flour and various foods;
  • Bleaching agents for papermaking, printing, and dyeing industries;
  • Cyanide breaking treatment of electroplating wastewater containing cyanide, decolorization treatment of printing and dyeing wastewater, and algae removal and sterilization treatment of industrial cooling water.
CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride

Certifications

CE Certificate Low Cost 50~10000g/H Chlorine Dioxide Generator for Phosphorus Pentafluoride

 

  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups